C&H GUHN48NM3AO Owner's Manual

Browse online or download Owner's Manual for Split-system air conditioners C&H GUHN48NM3AO. C&H GUHN48NM3AO Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 39
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
O
W
N
E
R
'
S M
A
N U
A
L
M
A
N U
A
L
C&H
A
IR C
O
N D
ITI
O
N
E
R S
Air Conditioner
FLOOR-TO-CEILING SERIES
MODELS:
indoor unit / outdoor unit
GTH18K3BI / GUHN24NK3AO
GTH24K3BI / GUHN24NK3AO
GTH36K3BI / GUHN36NM3AO
GTH48K3BI /
GUHN48NM3AO
Thanks for your selection of our Air-Conditioning Unit. Before use, please read this instruction
manual carefully and keep it properly to ensure correct use of this machine.
Page view 0
1 2 3 4 5 6 ... 38 39

Summary of Contents

Page 1 - Air Conditioner

O W N E R ' S M A N U A L M A N U A L C&H A IR C O N D ITI O N E R S Air Conditioner FLOOR-TO-CEILING SERIES MODELS: indoor u

Page 2 - WARNING!

9 Unit off display 10 Clock display 11 Confirm button 12 Increase button 13 Decrease button 14 Cacel/delete button 15 Single/group button 16

Page 3 - Timing display

Note: 1. For upper unit checks 16 lower units consecutively, there will be no more than 16 seconds delay

Page 4

Wire controller (with week timer functions) WARNING! ●Never install the wired controller where there is water leakage. ●Never knock, throw o

Page 5

1) ON/OFF(Fig.2) Press the “ON/OFF” button, the unit will start running. Press the “ON/OFF” button again, the unit will stop running.

Page 6 - Mode Setting

Setting temperature range under each mode: HEAT -------- 16℃~30℃ COOL -------- 16℃~30℃ DRY -------- 16℃~30℃ FAN -------- can not be set Au

Page 7 - Energy Saving Setting

the outdoor unit will be frosted resulting in low efficiency of heating, in which case, the controller will automatically start to defrost with DEFR

Page 8

In timing setting mode, press MODE button to select any desired setting object: Week (1-7), timer interval (1-4), timing (Timer on or Timer off time

Page 9 - Failure Display

In deleting timing status, press ▲ or ▼ button to select one day of a week, and then press TIMER button to confirm, in which

Page 10

blinking. Press▲ and ▼ to set lower-limit cooling temp (setting range is16-30) and then press ON/OFF to fix .Press ▲ and ▼ to set upper-li

Page 11

Fig.17 Codes Malfunction E0 Water pump malfunction E1 Compressor high-pressure protection E2 Indoor anti-freezing protection E3 Compressor lo

Page 12

Safety Considerations Please read this manual carefully before use and operate correctly as instructed in the manual. 1 You are specially warned

Page 13

CHECKING BEFORE CONT PROBLEM ACT THE SERVICE MAN OPERATION INSTRUCTIONS CAUSES RE CONTACT THE SERVICE MAN CCAA

Page 14

Indoor Unit Installation INSTALLATION INSTRUCTIONS INSTALLATION DIMENSIONS OF THE INDOOR UNIT When installing the indoor un

Page 15

Indoor Unit Installation INSTALLATION INSTRUCTIONS SELECTION OF INSTALLATION LOCATION. Such a place where cool air can be distributed t

Page 16

Fig.25 Indoor Unit Installation INSTALLATION INSTRUCTIONS Set the suspension bolt.(Use W3/8 or M10 size suspension bolts) Adjust the

Page 17

Outdoor Unit Installation INSTALLATION INSTRUCTIONS Fig.31 Fig.32 CAUTION

Page 18

Outdoor Unit Installation INS TALLATION INS T R UC T IONS Electric wiring connection GUHN18NK3AO GUHN2

Page 19

Profile Dimensions of Outdoor Unit Profile Dimensions of Outdoor Unit

Page 20

Schematic Diagram of Unit Line Connection INSTALLATION INSTRUCTIONS Electric wiring connection The section area of cables selected by

Page 21 - Indoor Unit Installation

Schematic Diagram of Unit Line Connection INSTALLATION INSTRUCTIONS GUHN18NK3AO GUHN24NK3AO GUHN36NM3AO GUHN48NM3AO

Page 22

Position and Method of Installing Wire Controller INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Position and Method of Installing Wire Contr

Page 23

9 Failure st atus display 10 Sleep st atus display 11 Mode key 12 Se t temperatur e incr ease key 13 Se t temperatur e decr ease key 14 Fa

Page 24 - Outdoor Unit

Position and Method of Installing Wire Controller INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Position and Method of Installing Wire C

Page 25 - Outdoor Unit

Position and Method of Installing Wire Controller INSTALLATION INSTRUCTIONS Caution: Before installing the electrical equipment, please pay atten

Page 26

PIPE PREPARATION OPERATION INSTRUCTIONS

Page 27 - Electric wiring

REFRIGERANT PIPING WORK OPERATION INSTRUCTIONS Item Model Size of Fitting Pipe (mm) Max. Pipe Length (m) Max. Height Diffe

Page 28

AIR PURGING AND CHECK OF PIPE LEAKAGE OPERATION INSTRUCTIONS

Page 29 - Controller

LIQUID PIPE AND DRAIN PIPE OPERATION INSTRUCTIONS

Page 30

DRAIN PIPING WORK OPERATION INSTRUCTIONS45

Page 31

ROUTINE CHECK AFTER INSTALLATION OPERATION INSTRUCTIONS Check after installation Items to be checked Possible malfunction Situation Has it bee

Page 32 - PIPE PREPARATION

Test condition Indoor side Outdoor side DB(C) WB(C) DB(C) WB(C) Nominal cooling 27 19 35 24 Nominal heating 20 -- 7 6 Rated cooling 32 23 43 26 L

Page 33 - REFRIGERANT PIPING WORK

This product must not be disposed together with the domestic waste. This product ha

Page 34 - OPERATION INSTRUCTIONS

Operating instructions of wire controller Turning ON/OFF unit Press the ON/OFF key, then the unit shall start up. Press the ON/OFF key

Page 35 - LIQUID PIPE AND DRAIN PIPE

Swing function setting SWING Press Swing button then the swing mode will be operated by the air conditioner. Repress Swing button once to s

Page 36 - DRAIN PIPING WORK

Operating Mode Setting SWING TIMER This key is pressed consecutively, the operating mode shall change as per the following sequence

Page 37

Timer Setting SWING TIMER When the unit is shut off, timing start can be set; After the unit is started up, timing shutoff can be set

Page 38 - TEST RUNNING

Display outdoor temperature Under normal conditions, the “OUT ENV” column shall only display the indoor temperature. Press the “SLEEP” key fo

Page 39

Failure Display SWING When there is failure in the unit operation, “ERROR” will flash on the LCD of the wire controller and

Comments to this Manuals